Multimeter test EX3 test mosfet with digital and analog multimeter

Test  mosfet   with   digital   and   analog   multimeter  

A  power  component  has  high current , high wattage  may be broken  as  shorted condition and  open condition.    Before  other  process testing , you may  firstly   check  shorted condition and  open condition. Testing  mosfet   has some detail and  all steps of testing  must be good so it is a good mosfet. If  any of  only testing step is fail   , the mosfet  is already  broken.



test  mosfet
                                        N   Channel   MOSFET  Symbol



Test  Mosfet

                                          P   Channel   MOSFET Symbol 


Step  to  test  mosfet  with  a  digital   multimeter

1.   Discharge mosfet .  short  3  terminals  D-G-S  together by using resistor legs or  other   metal wire. then remove resistor  leg.   After  shorting  3 terminals , do not touch any mosfet terminal again.  If  you touch it by error , it must re-discharge.  The area which  can touch and hold  is the black case of mosfet.

2.  Test  G and D  terminal , read the measured value.    Switch the test lead and read the measured value again.   A  good  mosfet ,   meter   will   display  "OL"   2   time.


Test  multimeter   Mosfet  Test
   Discharge mosfet .  short  3  terminals D-G-S  together  , G   D  S  is terminal arrangment.



Test  mosfet   with   multimeter
                                Test  G and D  terminal.  The  first testing.


Test  multimeter  Test  mosfet
                    Test  G and D  terminal.  The  second  testing ( switch the  test lead)


3.  Test  G and  S terminal , read the measured value.    Switch the test lead and read the measured value again.   A  good  mosfet ,   meter  will   display  " OL"   2  time.

Mosfet  Test
                                 Test  G and S  terminal.  The  first testing.


Test  multimeter  Test  mosfet  with     multimeter
                                  Test  G and D  terminal.  The  second  testing ( switch test lead)


4.  Test  D and  S terminal.   Use Ohm range to test D and S terminal  and read the measured value.  then switch the test lead  and  test again.  A good mosfet will display  " OL "   1 time  and  display high resistance  1  time. Some model   of  mosfet  has internal diode connect across D  and  S terminal , this case you can use diode range to test it.     Bad   mosfet will display differnt ways that is  , shored will display very  low resistance  0 Ohm  2 time  , open mosfet will display " OL"   2 time. 

วัดมอสเฟต  Mosfet    Test
      Test  D and  S terminal.   Use Ohm range will display high resistance  1 time.



Test  mosfet  with   multimeter
        Test  D and  S terminal.   Use Ohm range will display  " OL "  1 time.



Please be careful after discharge mosfet ,don't touch any terminal. Always hold mosfet at  insultated case.



Step  to  test  mosfet  with  a  digital   multimeter

1.   Discharge mosfet .  short  3  terminals  D-G-S  together  by using resistor legs or other   metal wire. then remove resistor leg.    After   short   3 terminals , do not touch any mosfet terminal again.  If  you touch it by error , it must   re-discharge.  The area which  can touch and hold is black case of mosfet.
2. Test  G and  D  terminal.  Set  range   to Rx10K and do zero ohm adjustment.   Connect test lead with D and G terminal    then read the measured value. Switch the test  lead and read the measured value  again.
Good   mosfet  , the  pointer  will  point  at   ∞     2   time.
3.  Test  G and  S  terminal.  Set range to Rx10K and  do  zero ohm adjustment.  Connect test lead with G and S terminal   then   read  the  measured value. Switch the test  lead and read the measured value  again.
Good   mosfet  ,the pointer  will point at   ∞    2   time.

Test  multimeter   Test  Mosfet
    Test  G and  D  terminal.  Good   mosfet  ,  the pointer  will  point   at   ∞     2   time.


Test  mosfet  with     multimeter
   Test  G and  S  terminal.  Good   mosfet  ,  the pointer  will point at   ∞     2   time.



    4.  Test  D  and  S  terminal.  Set  range  to Rx10 ( or Rx100  )   and  do  zero ohm adjustment. connect test lead with D and S terminal   then read the measured value. Switch the test  lead and read the measured value  again.
Good   mosfet  ,the pointer  will point at   low   resistance   1    time.
Good   mosfet  ,the pointer  will point at    ∞  (or  high resistance )  1    time.
( some model  it will  point   at  high   resistance instead of  ∞  )


วัดมอสเฟต  Test   Mosfet  check  mosfet
          Good   mosfet  ,the pointer  will  point at   low resistance   1    time.



Mosfet  test
      Good   mosfet  ,the pointer  will point at    ∞  (or  high resistance )  1    time.



Bad mosfet when  test  D  and  S  terminal  , shored condition will display  0 ohm  2 time.
Open condition  will display  ∞   2  time.
Test  Mosfet
Shored    mosfet   will display  0 ohm 2 time when test D and S terminal

                         Open mosfet   will display  ∞   2  time  when test D and S terminal